Procedure for updating firmware on TopSpin switch to level 555

This is a special procedure to also correct the recovery image on
the SIT level switches.

Prerequisites: 

-	SIT level switch
-	Switch must have access to ftp sever via management network

Procedure to update base firmware:
-	Download image and place on ftp server
-	Start a telnet session into the switch.
-	Login (USERID/PASSW0RD) with a zero
-	Type "en" to enable the interface
-	Type "dir image" to get a listing of the image files on the system
-	The file system can only store a maximum of two :"img" files, if the file 
	system on the switch contains two ".img" files you must delete at least one 
	before proceeding.  To delete a file type the following command 
	"delete image:image-name.img"  You will be asked to confirm file deletion.
-	Copy the new image on the switch.  
	Type "copy ftp://userid:password@ipaddress/TopspinIBMBC-TopspinOS-2.2.0-build555.img image:TopspinIBMBC-TopspinOS-2.2.0-build555.img".  
	Wait for the file transfer to complete
-	Install the image.  Type "install image:TopspinIBMBC-TopspinOS-2.2.0-build555.img"
-	Enter Configuration mode
	Type "configure"
-	Make the new image the boot image.  
	Type "boot-config primary-image-source TopspinOS-2.2.0/build555"
-	FROM THE MANAGEMENT MODULE WEB INTERFACE, restart the switch.  WAIT for the 
	switch to return a "Post complete" message on the I/O module status table.  
	This may take 8 to 10 MINUTES.  Do not interrupt the switch while it is posting.  
	WAIT for the switch to return the "POST COMPLETE" message.  It is normal during 
	process for the chassis fault light to turn on.  Again please continue to wait.